Refine
Year of publication
- 2024 (7)
- 2023 (15)
- 2022 (16)
- 2021 (14)
- 2020 (18)
- 2019 (5)
- 2018 (12)
- 2017 (7)
- 2016 (3)
- 2015 (3)
- 2014 (7)
- 2013 (1)
- 2012 (3)
- 2011 (1)
- 2010 (1)
- 2009 (1)
- 2008 (4)
- 2007 (1)
- 2005 (1)
- 2003 (1)
- 1995 (3)
- 1994 (5)
- 1993 (12)
- 1992 (9)
- 1991 (7)
- 1990 (13)
- 1989 (10)
- 1988 (4)
- 1987 (6)
- 1986 (8)
- 1984 (2)
- 1983 (2)
- 1980 (3)
- 1979 (1)
- 1978 (1)
- 1975 (4)
Document Type
- Article (153)
- Conference Proceeding (22)
- Report (12)
- Periodical Part (9)
- Book (7)
- Part of a Book (5)
- Course Material (1)
- Master's Thesis (1)
- Working Paper (1)
Has Fulltext
- yes (211)
Is part of the Bibliography
- no (211)
Keywords
- Euterentzündung (22)
- Logistik (20)
- Milchwirtschaft (20)
- Molkerei (13)
- bioplastics (9)
- biopolymers (9)
- land use (9)
- market data facts (9)
- Klebeverbindung (8)
- PPS (8)
Institute
- Fakultät II - Maschinenbau und Bioverfahrenstechnik (211) (remove)
Bürstenlose Generatorsysteme mit doppelt gespeisten Kaskadenmaschinen werden zurzeit für die regenerative Energieerzeugung z. B. mit Windkraftanlagen untersucht. Sie sind eine Alternative zu Generatorsystemen mit doppelt gespeisten Induktionsmaschinen. Kaskadenmaschinen arbeiten mit zwei Drehfeldern verschiedener Polpaarzahl. Im Stator befinden sich zwei Wicklungen für die beiden Polpaarzahlen oder eine Wicklung zur gleichzeitigen Erzeugung der beiden Drehfelder mit getrennten Anschlüssen für die beiden Drehfelder. Der Rotor trägt eine in sich kurzgeschlossene Wicklung, die gleichzeitig mit beiden Drehfeldern verkettet ist und deren Strom beide Drehfelder gleichzeitig erzeugt. Der vorliegende Beitrag beschreibt wie die elektromagnetischeWirkung unsymmetrischer Rotorwicklungen für Kaskadenmaschinen mit der Drehfeldanalyse behandelt werden kann. Die Rotorwicklungen dienen dazu, gleichzeitig beide Grundfelder der Kaskadenmaschine zu erzeugen. Dazu sind sie z. T. mit Wicklungszweigen aufgebaut, die in verschiedenen Knoten zusammen geschaltet sind. Aus Sicht der Statorwicklungen sind sie unsymmetrisch aufgebaut. Unsymmetrische Rotorwicklungen treten auch in Induktions- und Synchronmaschinen auf, z. B. bei Wicklungsfehlern, Stabbrüchen oder bei unsymmetrischen Anlaufkäfigen. Mit dem hier dargestellten Rechenverfahren wird die elektromagnetische Kopplung zwischen den Wicklungszweigen und zur Statorwicklung erfasst.
Bürstenlose Generatorsysteme mit doppelt gespeisten Kaskadenmaschinen werden zzt. für die regenerative Energieerzeugung z. B. mit Windkraftanlagen untersucht. Sie sind eine Alternative zu Generatorsystemen mit doppelt gespeisten Induktionsmaschinen. Kaskadenmaschinen arbeiten mit zwei Drehfeldern verschiedener Polpaarzahl. Im Stator befinden sich zwei Wicklungen für die beiden Polpaarzahlen oder eine Wicklung zur gleichzeitigen Erzeugung der beiden Drehfelder mit getrennten Anschlüssen für die beiden Drehfelder. Der Rotor trägt eine in sich kurzgeschlossene Wicklung, die gleichzeitig mit beiden Drehfeldern verkettet ist und deren Strom beide Drehfelder gleichzeitig erzeugt. Dieser Bericht behandelt die Flussdichte- und Durchflutungsverhältnisse der Wicklungen in Stator und Rotor für Kaskadenmaschinen. Dazu werden die Durchflutungen der Statorwicklungen und der Rotorwicklung für die beiden Polpaarzahlen bestimmt und die für die Wicklungsverluste wirksame Gesamtdurchflutung für verschiedene Polzahlkombinationen ermittelt. Die Ergebnisse werden mit Induktionsmaschinen für eine Polzahl verglichen.
Powder bed-based additive manufacturing processes offer an extended freedom in design and enable the processing of metals, ceramics, and polymers with a high level of relative density. The latter is a prevalent measure of process and component quality, which depends on various input variables. A key point in this context is the condition of powder beds. To enhance comprehension of their particle-level formation and facilitate process optimization, simulations based on the Discrete Element Method are increasingly employed in research. To generate qualitatively as well as quantitatively reliable simulation results, an adaptation of the contact model parameterization is necessary. However, current adaptation methods often require the implementation of models that significantly increase computational effort, therefore limiting their applicability. To counteract this obstacle, a sophisticated formula-based adaptation and evaluation method is presented in this research. Additionally, the developed method enables accelerated parameter determination with limited experimental effort. Thus, it represents an integrative component, which supports further research efforts based on the Discrete Element Method by significantly reducing the parameterization effort. The universal nature of deducting this method also allows its adaptation to similar parameterization problems and its implementation in other fields of research.
Techno-economic analysis that allocate costs to the energy flows of energy systems are helpful to understand the formation of costs within processes and to increase the cost efficiency. For the economic evaluation, the usefulness or quality of the energy is of great importance. In exergy-based methods, this is considered by allocating costs to the exergy instead of energy. As exergy represents the ability of performing work, it is often named the useful part of energy. In contrast, the anergy, the part of energy, which cannot perform work, is often assumed to be not useful.
However, heat flows as used e.g. in domestic heating are always a mixture of a relative small portion of exergy and a big portion of anergy. Although of lower quality, the anergy is obviously useful for these applications. The question is, whether it makes sense to differentiate between exergy and anergy and take both properties into account for the economic evaluation.
To answer this question, a new methodical concept based on the definition of an anergy-exergy cost ratio is compared to the commonly applied approaches of considering either energy or exergy as the basis for economic evaluation. These three different approaches for the economic analysis of thermal energy systems are applied to an exemplary heating system with thermal storages. It is shown that the results of the techno-economic analysis can be improved by giving anergy an economic value and that the proposed anergy-cost ratio allows a flexible adaptation of the evaluation depending on the economic constraints of a system.
Parametric study of piezoresistive structures in continuous fiber reinforced additive manufacturing
(2024)
Recent advancements in fiber reinforced additive manufacturing leverage the piezoresistivity of continuous carbon fibers. This effect enables the fabrication of structural components with inherent piezoresistive properties suitable for load measurement or structural monitoring. These are achieved without necessitating additional manufacturing or assembly procedures. However, there remain unexplored variables within the domain of continuous fiber-reinforced additive manufacturing. Crucially, the roles of fiber curvature radii and sensing fiber bundle counts have yet to be comprehensively addressed. Additionally, the compression-sensitive nature of printed carbon fiber-reinforced specimens remains a largely unexplored research area. To address these gaps, this study presents experimental analyses on tensile and three-point flexural specimens incorporating sensing carbon fiber strands. All specimens were fabricated with three distinct curvature radii. For the tensile specimens, the number of layers was also varied. Sensing fiber bundles were embedded on both tensile and compression sides of the flexural specimens. Mechanical testing revealed a linear-elastic behavior in the specimens. It was observed that carbon fibers supported the majority of the load, leading to brittle fractures. The resistance measurements showed a dependence on both the number of sensing layers and the radius of curvature, and exhibited a slight decreasing trend in the cyclic tests. Compared with the sensors subjected to tensile stress, the sensors embedded on the compression side showed a lower gauge factor.
Compounds that exhibit the spin crossover effect are known to show a change of spin states through external stimuli. This reversible switching of spin states is accompanied by a change of the properties of the compound. Complexes, like iron (II)-triazole complexes, that exhibit this behavior at ambient temperature are often discussed for potential applications. In previous studies we synthesized iron (II)-triazole complexes and implemented them into electrospun nanofibers. We used Mössbauer spectroscopy in first studies to prove a successful implementation with maintaining spin crossover properties. Further studies from us showed that it is possible to use different electrospinning methods to either do a implementation or a deposition of the synthesized solid SCO material into or onto the polymer nanofibers. We now used a solvent in which both, the used iron (II)-triazole complex [Fe(atrz)3](2 ns)2 and three different polymers (Polyacrylonitrile, Polymethylmethacrylate and Polyvinylpyrrolidone), are soluble. This shall lead to a higher homogeneous distribution of the complex along the nanofibers. Mössbauer spectroscopy and other measurements are therefore in use to show a successful implementation without any significant changes to the complex.
Complexes like iron (II)-triazoles exhibit spin crossover behavior at ambient temperature and are often considered for possible application. In previous studies, we implemented complexes of this type into polymer nanofibers and first polymer-based optical waveguide sensor systems. In our current study, we synthesized complexes of this type, implemented them into polymers and obtained composites through drop casting and doctor blading. We present that a certain combination of polymer and complex can lead to composites with high potential for optical devices. For this purpose, we used two different complexes [Fe(atrz)3](2 ns)2 and [Fe(atrz)3]Cl1.5(BF4)0.5 with different polymers for each composite. We show through transmission measurements and UV/VIS spectroscopy that the optical properties of these composite materials can reversibly change due to the spin crossover effect.
The increasing variety of combinations of different building technology components offers a high potential for energy and cost savings in today's buildings. However, in most cases, this potential is not yet fully exploited due to the lack of intelligent supervisory control systems that are required to manage the complexity of the resulting overall systems. In this article, we present the implementation of a mixed-integer nonlinear model predictive control approach as a smart realtime building energy management system. The presented methodology is based on a forward-looking optimization of the overall energy costs. It takes into account energy demand forecasts and varying electricity market prices. We achieve real-time capability of the controller by applying a decomposition approach, which approximates the optimal solution of the underlying mixed-integer optimal control problem by convexification and rounding of the relaxed solution. The quality of the suboptimal solution is evaluated by comparison with the globally optimal solution obtained by the dynamic programming method. Based on a real-world scenario, we demonstrate that utilization of the real-time capable mixedinteger nonlinear model predictive control approach in a building control system leads to savings of 16% in the total operating costs and 13% in primary energy compared to the state-of-the-art control strategy without any loss of comfort for the residents.
Bürstenlose Generatorsysteme mit doppelt gespeisten Kaskadenmaschinen werden zzt. für die regenerative Energieerzeugung z. B. mit Windkraftanlagen untersucht. Sie sind eine Alternative zu Generatorsystemen mit doppelt gespeisten Induktionsmaschinen. Kaskadenmaschinen arbeiten mit zwei Drehfeldern verschiedener Polpaarzahl. Im Stator befinden sich zwei Wicklungen für die beiden Polpaarzahlen oder eine Wicklung zur gleichzeitigen Erzeugung der beiden Drehfelder mit getrennten Anschlüssen für die beiden Drehfelder. Der Rotor trägt eine in sich kurzgeschlossene Wicklung, die gleichzeitig mit beiden Drehfeldern verkettet ist und deren Strom beide Drehfelder gleichzeitig erzeugt. Dieser Bericht behandelt die sinnvollen Polpaarzahlen für Kaskadenmaschinen. Dazu werden die Polpaarzahlkombinationen hinsichtlich ihrer parasitären Effekte und Ausführungsmöglichkeiten qualitativ bewertet.
The miniaturized Mössbauer-spectrometer (MIMOS II), originally devised by Göstar Klingelhöfer, is further developed by the Renz group at the Leibniz University Hanover in cooperation with the Hanover University of Applied Sciences and Arts. A new processing unit with a two-dimensional (2D) data acquisition was developed by M. Jahns. The advantage of this data acquisition is that no thresholds need to be set before the measurement. The energy of each photon is determined and stored with the velocity of the drive. After the measurement, the relevant area can be selected for the Mössbauer spectrum. Now we have expanded the evaluation unit with a power supply for a MIMOS drive and a MIMOS PIN detector. So we have a very compact MIMOS transmissions measurement setup. With this setup it is possible to process the signals of two detectors serially. Currently we are working on a parallel signal processing.
Mixed-integer NMPC for real-time supervisory energy management control in residential buildings
(2023)
In recent years, building energy supply and distribution systems have become more complex, with an increasing number of energy generators, stores, flows, and possible combinations of operating modes. This poses challenges for supervisory control, especially when balancing the conflicting goals of maximizing comfort while minimizing costs and emissions to contribute to global climate protection objectives. Mixed-integer nonlinear model predictive control is a promising approach for intelligent real-time control that is able to properly address the specific characteristics and restrictions of building energy systems. We present a strategy that utilizes a decomposition approach, combining partial outer convexification with the Switch-Cost Aware Rounding procedure to handle switching behavior and operating time constraints of building components in real-time. The efficacy is demonstrated through practical applications in a single-family home with a combined heat and power unit and in a multi-family apartment complex with 18 residential units. Simulation studies show high correspondence to globally optimal solutions with significant cost savings potential of around 19%.
The aim of this cross-sectional study was to investigate associated factors of the severity of clinical mastitis (CM). Milk samples of 249 cases of CM were microbiologically examined, of which 27.2% were mild, 38.5% moderate, and 34.3% severe mastitis. The samples were incubated aerobically and anaerobically to investigate the role of aerobic and anaerobic microorganisms. In addition, the pathogen shedding was quantitatively examined, and animal individual data, outside temperature and relative humidity, were collected to determine associated factors for the severity of CM. The pathogen isolated the most was Escherichia coli (35.2%), followed by Streptococcus spp. (16.4%). Non-aureus staphylococci (NaS) (15.4%) and other pathogens (e.g., Staphylococcus aureus, coryneforms) (15.4%) were the pathogens that were isolated the most for mild mastitis. Moderate mastitis was mostly caused by E. coli (38%). E. coli was also the most common pathogen in severe mastitis (50.6%), followed by Streptococcus spp. (16.4%), and Klebsiella spp. (10.3%). Obligate anaerobes (Clostridium spp.) were isolated in one case (0.4%) of moderate mastitis. The mortality rate (deceased or culled due to the mastitis in the following two weeks) was 34.5% for severe mastitis, 21.7% for moderate mastitis, and 4.4% for mild mastitis. The overall mortality rate of CM was 21.1%. The pathogen shedding (back logarithmized) was highest for severe mastitis (55,000 cfu/mL) and E. coli (91,200 cfu/mL). High pathogen shedding, low previous somatic cell count (SCC) before mastitis, high outside temperature, and high humidity were associated with severe courses of mastitis.
The aim of this cross-sectional study was to investigate the occurrence of bacteremia in severe mastitis cases of dairy cows. Milk and corresponding blood samples of 77 cases of severe mastitis were bacteriologically examined. All samples (milk and blood) were incubated aerobically and anaerobically to also investigate the role of obligate anaerobic microorganisms in addition to aerobic microorganisms in severe mastitis. Bacteremia occurred if identical bacterial strains were isolated from milk and blood samples of the same case. In addition, pathogen shedding was examined, and the data of animals and weather were collected to determine associated factors for the occurrence of bacteremia in severe mastitis. If Gram-negative bacteria were detected in milk samples, a Limulus test (detection of endotoxins) was also performed for corresponding blood samples without the growth of Gram-negative bacteria. In 74 cases (96.1%), microbial growth was detected in aerobically incubated milk samples. The most-frequently isolated bacteria in milk samples were Escherichia (E.) coli (48.9%), Streptococcus (S.) spp. (18.1%), and Klebsiella (K.) spp. (16%). Obligatory anaerobic microorganisms were not isolated. In 72 cases (93.5%) of the aerobically examined blood samples, microbial growth was detected. The most-frequently isolated pathogens in blood samples were non-aureus Staphylococci (NaS) (40.6%) and Bacillus spp. (12.3%). The Limulus test was positive for 60.5% of cases, which means a detection of endotoxins in most blood samples without the growth of Gram-negative bacteria. Bacteremia was confirmed in 12 cases (15.5%) for K. pneumoniae (5/12), E. coli (4/12), S. dysgalactiae (2/12), and S. uberis (1/12). The mortality rate (deceased or culled) was 66.6% for cases with bacteremia and 34.1% for cases without bacteremia. High pathogen shedding and high humidity were associated with the occurrence of bacteremia in severe mastitis.
In this paper a new rotor position observer for permanent magnet synchronous machines (PMSM) based on an Extended-Kalman-Filter (EKF) is presented. With this method, just one single EKF is sufficent to evaluate the position information from electromotive force (EMF) and anisotropy. Thus, the PMSM can be controlled for the entire speed range without a position sensor and without the need to switch or synchronize between different observers. The approach covers online estimation of permanent magnetic field and mechanical load. The resulting EKF-based rotor position estimator is embedded in the existing cascaded control concept of the PMSM without need of additional angle trackers or signal filters. The experimental validation for the position sensorless control shows optimized dynamic behaviour.
To effectively prevent and control bovine mastitis, farmers and their advisors need to take infection pathways and durations into account. Still, studies exploring both aspects through molecular epidemiology with sampling of entire dairy cow herds over longer periods are scarce. Therefore, quarter foremilk samples were collected at 14-d intervals from all lactating dairy cows (n = 263) over 18 wk in one commercial dairy herd. Quarters were considered infected with Staphylococcus aureus, Streptococcus uberis, or Streptococcus dysgalactiae when ≥100 cfu/mL of the respective pathogen was detected, or with Staphylococcus epidermidis or Staphylococcus haemolyticus when ≥500 cfu/mL of the respective pathogen was detected. All isolates of the mentioned species underwent randomly amplified polymorphic DNA (RAPD)-PCR to explore strain diversity and to distinguish ongoing from new infections. Survival analysis was used to estimate infection durations. Five different strains of Staph. aureus were isolated, and the most prevalent strain caused more than 80% of all Staph. aureus infections (n = 46). In contrast, 46 Staph. epidermidis and 69 Staph. haemolyticus strains were isolated, and none of these caused infections in more than 2 different quarters. The 3 most dominant strains of Strep. dysgalactiae (7 strains) and Strep. uberis (18 strains) caused 81% of 33 and 49% of 37 infections in total, respectively. The estimated median infection duration for Staph. aureus was 80 d, and that for Staph. epidermidis and Staph. haemolyticus was 28 and 22 d, respectively. The probability of remaining infected with Strep. dysgalactiae or Strep. uberis for more than 84 and 70 d was 58.7 and 53.5%, respectively. Staphylococcus epidermidis and Staph. haemolyticus were not transmitted contagiously and the average infection durations were short, which brings into question whether antimicrobial treatment of intramammary infections with these organisms is justified. In contrast, infections with the other 3 pathogens lasted longer and largely originated from contagious transmission.
To design cost-effective prevention strategies against mastitis in dairy cow farms, knowledge about infection pathways of causative pathogens is necessary. Therefore, we investigated the reservoirs of bacterial strains causing intramammary infections in one dairy cow herd. Quarter foremilk samples (n = 8056) and milking- and housing-related samples (n = 251; from drinking troughs, bedding material, walking areas, cow brushes, fly traps, milking liners, and milker gloves), were collected and examined using culture-based methods. Species were identified with MALDI-TOF MS, and selected Staphylococcus and Streptococcus spp. typed with randomly amplified polymorphic DNA-PCR. Staphylococci were isolated from all and streptococci from most investigated locations. However, only for Staphylococcus aureus, matching strain types (n = 2) were isolated from milk and milking-related samples (milking liners and milker gloves). Staphylococcus epidermidis and Staphylococcus haemolyticus showed a large genetic diversity without any matches of strain types from milk and other samples. Streptococcus uberis was the only Streptococcus spp. isolated from milk and milking- or housing-related samples. However, no matching strains were found. This study underlines the importance of measures preventing the spread of Staphylococcus aureus between quarters during milking.
Antimicrobials are widely used to cure intramammary infections (IMI) in dairy cows during the dry period (DP). Nevertheless, the IMI cure is influenced by many factors and not all quarters benefit from antimicrobial dry cow treatment (DCT). To evaluate the true effect of antibiotic DCT compared to self-cure and the role of causative pathogens on the IMI cure, a retrospective cross-sectional study was performed. The analysis included 2987 quarters infected at dry-off (DO). Information on DCT, causative pathogens, somatic cell count, milk yield, amount of lactation, Body Condition Score, and season and year of DO were combined into categorical variables. A generalized linear mixed model with a random cow, farm and year effect and the binary outcome of bacteriological cure of IMI during the DP was conducted. In the final model, a significant effect (p < 0.05) on DP cure was seen for the DO season and the category of causative pathogens (categories being: Staphylococcus aureus, non-aureus staphylococci, streptococci, coliforms, ‘other Gram-negative bacteria’, ‘other Gram positive bacteria’, non-bacterial infections and mixed infections), while antibiotic DCT (vs. non-antibiotic DCT) only showed a significant effect in combination with the pathogen categories streptococci and ‘other Gram-positive bacteria’.
One of the main concerns of this publication is to furnish a more rational basis for discussing bioplastics and use fact-based arguments in the public discourse. Furthermore, “Biopolymers – facts and statistics” aims to provide specific, qualified answers easily and quickly for decision-makers in particular from public administration and the industrial sector. Therefore, this publication is made up like a set of rules and standards and largely foregoes textual detail. It offers extensive market-relevant and technical facts presented in graphs and charts, which means that the information is much easier to grasp. The reader can expect comparative market figures for various materials, regions, applications, process routes, agricultural land use, water use or resource consumption, production capacities, geographic distribution, etc.
During machine milking, pathogenic microorganisms can be transmitted from cow to cow through liners. Therefore, in Germany, a spray method for the intermediate disinfection of the milking cluster is often used for prevention. This method of cluster disinfection is easy to perform, requires little time and no extra materials, and the disinfection solution is safe from outside contamination in the spray bottle. Since no data on a systematic efficacy trial are available, the aim of this study was to determine the microbial reduction effect of intermediate disinfection. Therefore, laboratory and field trials were conducted. In both trials, two sprays of 0.85 mL per burst of different disinfectant solutions were sprayed into the contaminated liners. For sampling, a quantitative swabbing method using a modified wet–dry swab (WDS) technique based on DIN 10113-1: 1997-07 was applied. Thus, the effectiveness of disinfectants based on Peracetic Acid, Hydrogen Peroxide and Plasma-Activated Buffered Solution (PABS) was compared. In the laboratory trial, the inner surfaces of liners were contaminated with pure cultures of Escherichia (E.) coli, Staphylococcus (S.) aureus, Streptococcus (Sc.) uberis and Sc. agalactiae. The disinfection of the contaminated liners with the disinfectants resulted in a significant reduction in bacteria with values averaging 1 log for E. coli, 0.7 log for S. aureus, 0.7 log for Sc. uberis and 0.8 log for Sc. agalactiae. The highest reduction was obtained for contamination with E. coli (1.3 log) and Sc. uberis (0.8 log) when PABS was applied and for contamination with S. aureus (1.1 log) and Sc. agalactiae (1 log) when Peracetic Acid Solution (PAS) was used. Treatment with sterile water only led to an average reduction of 0.4 log. In the field trial, after the milking of 575 cows, the liners were disinfected and the total microorganism count from the liner surface was performed. The reduction was measured against an untreated liner within the cluster. Although a reduction in microorganisms was achieved in the field trial, it was not significant. When using PAS, a log reduction of 0.3 was achieved; when using PABS, a log reduction of 0.2 was obtained. The difference between the two disinfection methods was also not significant. Treatment with sterile water only led to a reduction of 0.1 log. The results show that spray disinfection under these circumstances does result in a reduction in the bacteria on the milking liner surface, but for effective disinfection a higher reduction would be preferred.