Refine
Year of publication
- 2019 (2)
Document Type
- Article (1)
- Conference Proceeding (1)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- Anonymization (1)
- Asymmetric encryption (1)
- Case Management (1)
- Data Management (1)
- Lymphknoten (1)
- Magnetometer (1)
- Privacy by Design (1)
- Prostatakrebs (1)
- Pseudonymization (1)
- SPION (1)
Institute
Research into new forms of care for complex chronic diseases requires substantial efforts in the collection, storage, and analysis of medical data. Additionally, providing practical support for those who coordinate the actual care management process within a diversified network of regional service providers is also necessary. For instance, for stroke units, rehabilitation partners, ambulatory actors, as well as health insurance funds. In this paper, we propose the concept of comprehensive and practical receiver-oriented encryption (ROE) as a guiding principle for such data-intensive, research-oriented case management systems, and
illustrate our concept with the example of the IT infrastructure of the project STROKE OWL.
Radioisotope-guided sentinel lymph node dissection (sLND) has shown high diagnostic reliability in prostate (PCa) and other cancers. To overcome the limitations of the radioactive tracers, magnetometer-guided sLND using superparamagnetic iron oxide nanoparticles (SPIONs) has been successfully used in PCa. This prospective study (SentiMag Pro II, DRKS00007671) determined the diagnostic accuracy of magnetometer-guided sLND in intermediate- and high-risk PCa. Fifty intermediate- or high-risk PCa patients (prostate-specific antigen (PSA) >= 10 ng/mL and/or Gleason score >= 7; median PSA 10.8 ng/mL, IQR 7.4–19.2 ng/mL) were enrolled. After the intraprostatic SPIONs injection a day earlier, patients underwent magnetometer-guided sLND and extended lymph node dissection (eLND, followed by radical prostatectomy. SLNs were detected in in vivo and in ex vivo samples. Diagnostic accuracy of sLND was assessed using eLND as the reference. SLNs were detected in all patients (detection rate 100%), with 447 sentinel lymph nodes SLNs (median 9, IQR 6–12) being identified and 966 LNs (median 18, IQR 15–23) being removed. Thirty-six percent (18/50) of patients had LN metastases (median 2, IQR 1–3). Magnetometer-guided sLND had 100% sensitivity, 97.0% specificity, 94.4% positive predictive value, 100% negative predictive value, 0.0% false negative rate, and 3.0% additional diagnostic value (LN metastases only in SLNs outside the eLND template). In vivo, one positive SLN/LN-positive patient was missed, resulting in a sensitivity of 94.4%. In conclusion, this new magnetic sentinel procedure has high accuracy for nodal staging in intermediate- and high-risk PCa. The reliability of intraoperative SLN detection using this magnetometer system requires verification in further multicentric studies.