Refine
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- 18F-FET-PET/CT (1)
- Amino acid PET (1)
- Cyber-Knife (1)
- CyberKnife (1)
- Cyberknife (1)
- Dynamic 18F-FET-PET/CT (1)
- Neuralgie (1)
- Neuropathic pain (1)
- Radiation necrosis (1)
- Radiochirurgie (1)
Institute
Objective
Cyberknife robotic radiosurgery (RRS) provides single-session high-dose radiotherapy of brain tumors with a steep dose gradient and precise real-time image-guided motion correction. Although RRS appears to cause more radiation necrosis (RN), the radiometabolic changes after RRS have not been fully clarified. 18F-FET-PET/CT is used to differentiate recurrent tumor (RT) from RN after radiosurgery when MRI findings are indecisive. We explored the usefulness of dynamic parameters derived from 18F-FET PET in differentiating RT from RN after Cyberknife treatment in a single-center study population.
Methods
We retrospectively identified brain tumor patients with static and dynamic 18F-FET-PET/CT for suspected RN after Cyberknife. Static (tumor-to-background ratio) and dynamic PET parameters (time-activity curve, time-to-peak) were quantified. Analyses were performed for all lesions taken together (TOTAL) and for brain metastases only (METS). Diagnostic accuracy of PET parameters (using mean tumor-to-background ratio >1.95 and time-to-peak of 20 min for RT as cut-offs) and their respective improvement of diagnostic probability were analyzed.
Results
Fourteen patients with 28 brain tumors were included in quantitative analysis. Time-activity curves alone provided the highest sensitivities (TOTAL: 95%, METS: 100%) at the cost of specificity (TOTAL: 50%, METS: 57%). Combined mean tumor-to-background ratio and time-activity curve had the highest specificities (TOTAL: 63%, METS: 71%) and led to the highest increase in diagnosis probability of up to 16% p. – versus 5% p. when only static parameters were used.
Conclusions
This preliminary study shows that combined dynamic and static 18F-FET PET/CT parameters can be used in differentiating RT from RN after RRS.
Background: Stereotactic radiosurgery (SRS) is an effective treatment for trigeminal neuralgia (TN). Nevertheless, a proportion of patients will experience recurrence and treatment-related sensory disturbances. In order to evaluate the predictors of efficacy and safety of image-guided non-isocentric radiosurgery, we analyzed the impact of trigeminal nerve volume and the nerve dose/volume relationship, together with relevant clinical characteristics.
Methods: Two-hundred and ninety-six procedures were performed on 262 patients at three centers. In 17 patients the TN was secondary to multiple sclerosis (MS). Trigeminal pain and sensory disturbances were classified according to the Barrow Neurological Institute (BNI) scale. Pain-free-intervals were investigated using Kaplan Meier analyses. Univariate and multivariate Cox regression analyses were performed to identify predictors.
Results: The median follow-up period was 38 months, median maximal dose 72.4 Gy, median target nerve volume 25mm3, and median prescription dose 60 Gy. Pain control rate (BNI I-III) at 6, 12, 24, 36, 48, and 60 months were 96.8, 90.9, 84.2, 81.4, 74.2, and 71.2%, respectively. Overall, 18% of patients developed sensory disturbances. Patients with volume ≥ 30mm3 were more likely to maintain pain relief (p = 0.031), and low integral dose (< 1.4 mJ) tended to be associated with more pain recurrence than intermediate (1.4–2.7 mJ) or high integral dose (> 2.7 mJ; low vs. intermediate: log-rank test, χ2 = 5.02, p = 0.019; low vs. high: log-rank test, χ2 = 6.026, p = 0.014). MS, integral dose, and mean dose were the factors associated with pain recurrence, while re-irradiation and MS were predictors for sensory disturbance in the multivariate analysis.
Conclusions: The dose to nerve volume ratio is predictive of pain recurrence in TN, and re-irradiation has a major impact on the development of sensory disturbances after non-isocentric SRS. Interestingly, the integral dose may differ significantly in treatments using apparently similar dose and volume constraints.