Refine
Year of publication
Document Type
- Conference Proceeding (21) (remove)
Has Fulltext
- yes (21)
Is part of the Bibliography
- no (21)
Keywords
- Energiemanagement (7)
- Angewandte Botanik (6)
- Digitalisierung (6)
- Erkennungssoftware (6)
- Gepresste Pflanzen (6)
- Herbar Digital (6)
- Herbarium (6)
- OCR (6)
- Recognition software (6)
- Virtualisierung (6)
- Energieeffizienz (4)
- PROFInet (3)
- energy management (3)
- Computersicherheit (2)
- Ethernet (2)
- PROFINET Security (2)
- energy efficiency (2)
- technical energy management (2)
- 2D data processing (1)
- Anforderungsermittlung (1)
- Automation (1)
- AutomationML (1)
- Automatisierungssystem (1)
- Big Data (1)
- Big-Data-Datenplattform (1)
- Codegenerierung (1)
- Cyber-Security (1)
- Data handling (1)
- Datenerfassung (1)
- Digital storage (1)
- Dimension 2 (1)
- Energieaufnahme (1)
- Feldgeräte (1)
- Framework <Informatik> (1)
- Funktionsgenerator (1)
- IBM PC (1)
- ICS Security (1)
- IT security (1)
- IT-Sicherheit (1)
- Industrial Security (1)
- Industrie 4.0 (1)
- Informationsmodell (1)
- Informationsmodellierung (1)
- Internet der Dinge (1)
- Knowledge Life Cycle (1)
- Kommunikation (1)
- Kryptologie (1)
- Lastmanagement (1)
- Lastverteilung <Energietechnik> (1)
- MIMOS II (1)
- Messwerterfassung (1)
- Mikroprozessor (1)
- Mößbauer-Spektrometer (1)
- OPC UA (1)
- OT Security (1)
- OT-Security (1)
- Requirements engineering (1)
- Schaltungstechnik (1)
- Secure communication (1)
- Security Knowledge (1)
- Security Ontology (1)
- Signal processing (1)
- Signaltechnik (1)
- Signalverarbeitung (1)
- Technisches Energiemanagementsystem (tEnMS) (1)
- Transmission measurement setup (1)
- aggregation server (1)
- code generation (1)
- cyber security (1)
- energy data (1)
- energy data information model (1)
- energy information model (1)
- energy monitoring (1)
- energy profiles (1)
- information modeling (1)
- measurement data acquisition (1)
- security (1)
- security protocol extensions (1)
- standardized semantics (1)
Institute
- Fakultät I - Elektro- und Informationstechnik (21) (remove)
In industrial production facilities, technical Energy Management Systems are used to measure, monitor and display energy consumption related information. The measurements take place at the field device level of the automation pyramid. The measured values are recorded and processed at the control level. The functionalities to monitor and display energy data are located at the MES level of the automation pyramid. So the energy data from all PLCs has to be aggregated, structured and provided for higher level systems. This contribution introduces a concept for an Energy Data Aggregation Layer, which provides the functionality described above. For the implementation of this Energy Data Aggregation Layer, a combination of AutomationML and OPC UA is used.
Einfluss von Industrie 4.0 auf die Anwendbarkeit von Lastmanagement in der industriellen Produktion
(2018)
Technische Energiemanagementsysteme (kurz und im Folgenden tEnMS) in der produzierenden Industrie dienen heute meinst dem Messen, Speichern und Auswerten von Energieverbrauchsdaten. Allerdings besteht auch die Möglichkeit der Vorhersage und aktiven Einflussnahme auf die Energieaufnahme von Produktionsumgebungen durch das tEnMS. Derartige Funktionen werden als Prognose- und Lastmanagementfunktionen bezeichnet. Industrielle Produktionsumgebungen erfahren im Rahmen von Industrie 4.0 einen Wandel. Dieser Beitrag soll aufzeigen, wie tEnMS durch den beschriebenen Wandel beeinflusst werden und welche Chancen sich daraus für zukünftige tEnMS ergeben.
PROFINET Security: A Look on Selected Concepts for Secure Communication in the Automation Domain
(2023)
We provide a brief overview of the cryptographic security extensions for PROFINET, as defined and specified by PROFIBUS & PROFINET International (PI). These come in three hierarchically defined Security Classes, called Security Class 1, 2 and 3. Security Class 1 provides basic security improvements with moderate implementation impact on PROFINET components. Security Classes 2 and 3, in contrast, introduce an integrated cryptographic protection of PROFINET communication. We first highlight and discuss the security features that the PROFINET specification offers for future PROFINET products. Then, as our main focus, we take a closer look at some of the technical challenges that were faced during the conceptualization and design of Security Class 2 and 3 features. In particular, we elaborate on how secure application relations between PROFINET components are established and how a disruption-free availability of a secure communication channel is guaranteed despite the need to refresh cryptographic keys regularly. The authors are members of the PI Working Group CB/PG10 Security.
Big-Data-Datenplattformen werden immer beliebter, um große Datenmengen bei Bedarf analysieren zu können. Zu den fünf gängigsten Big-Data-Verarbeitungsframeworks gehören Apache Hadoop, Apache Storm, Apache Samza, Apache Spark, und Apache Flink. Zwar unterstützen alle fünf Plattformen die Verarbeitung großer Datenmengen, doch unterscheiden sich diese Frameworks in ihren Anwendungsbereichen und der zugrunde liegenden Architektur. Eine Reihe von Studien hat sich bereits mit dem Vergleich dieser Big-Data-Frameworks befasst, indem sie sie anhand eines bestimmten Leistungsindikators bewertet haben. Die IT-Sicherheit dieser Frameworks wurde dabei jedoch nicht betrachtet. In diesem Beitrag werden zunächst allgemeine Anforderungen und Anforderungen an die IT-Sicherheit der Datenplattformen definiert. Anschließend werden die Datenplattform-Konzepte unter Berücksichtigung der aufgestellten Anforderungen analysiert und gegenübergestellt.
Industrial Control Systems (ICS) succumb to an ever evolving variety of threats. Additionally, threats are increasing in number and get more complex. This requires a holistic and up-to-date security concept for ICS as a whole. Usually security concepts are applied and updated based on regularly performed ICS security assessments. Such ICS security assessments require high effort and extensive knowledge about ICS and its security. This is often a problem for small and mediumsized enterprises (SME), which do not have sufficient respective sufficiently skilled human resources. This paper defines in a first step requirements on the knowledge needed to perform an ICS security assessment and the life cycle of this knowledge. Afterwards the ICS security knowledge and its life cycle are developed and discussed considering the requirements and related work.
The research project "Herbar Digital" was started in 2007 with the aim to digitize 3.5 million dried plants on paper sheets belonging to the Botanic Museum Berlin in Germany. Frequently the collector of the plant is unknown, so a procedure had to be developed in order to determine the writer of the handwriting on the sheet. In the present work the static character was transformed into a dynamic form. This was done with the model of an inert ball which was rolled along the written character. During this off-line writer recognition, different mathematical procedures were used such as the reproduction of the write line of individual characters by Legendre polynomials. When only one character was used, a recognition rate of about 40% was obtained. By combining multiple characters, the recognition rate rose considerably and reached 98.7% with 13 characters and 93 writers (chosen randomly from the international IAM-database [3]). A global statistical approach using the whole handwritten text resulted in a similar recognition rate. By combining local and global methods, a recognition rate of 99.5% was achieved.
Our research project, "Rationalizing the virtualization of botanical document material and their usage by process optimization and automation (Herbar-Digital)" started on July 1, 2007 and will last until 2012. Its long-term aim is the digitization of the more than 3,5 million specimens in the Berlin Herbarium. The University of Applied Sciences and Arts in Hannover collaborates with the department of Biodiversity Informatics at the BGBM (Botanic Garden and Botanical Museum Berlin-Dahlem) headed by Walter Berendsohn. The part of Herbar-Digital here presented deals with the analysis of the generated high resolution images (10,400 lines x 7,500 pixel).
Das Forschungsprojekt „Herbar Digital” startete 2007 mit dem Ziel der Digitalisierung des Bestands von mehr als 3,5 Millionen getrockneter Pflanzen bzw. Pflanzenteile auf Papierbögen (Herbarbelege) des Botanischen Museums Berlin. Die Aufgabe des Autors ist die Analyse der hochaufgelösten Bilder mit 10400 Zeilen und 7500 Spalten. Die Herbarbelege können außerdem unterschiedliche Objekte enthalten wie Umschläge mit zusätzlichen Pflanzenteilen, gedruckte oder handgeschriebene Etiketten, Farbtabellen, Maßstäbe, Stempel, Barcodes, farbige „Typus-Etiketten“ und handschriftliche Anmerkungen direkt auf dem Beleg. Die schriftlichen Anmerkungen, insbesondere in Handschrift, sind von besonderem Interesse. Kommerzielle OCR-Software kann oftmals Schrift in komplexen Umgebungen nicht lokalisieren, wie sie häufig auf den Herbarbelegen vorliegt, auf denen Schrift zwischen Blättern, Wurzeln und anderen Objekten angeordnet ist. Im folgenden wird eine Methode vorgestellt, die es ermöglicht, Schriftpassagen im Bild automatisch zu finden.
Requirements for an energy data information model for a communication-independent device description
(2021)
With the help of an energy management system according to ISO 50001, industrial companies obtain the opportunities to reduce energy consumption and to increase plant efficiencies. In such a system, the communication of energy data has an important function. With the help of so-called energy profiles (e.g. PROFIenergy), energy data can be communicated between the field level and the higher levels via proven communication protocols (e.g. PROFINET). Due to the fact that in most cases several industrial protocols are used in an automation system, the problem is how to transfer energy data from one protocol to another with as less effort as possible. An energy data information model could overcome this problem and describe energy data in a uniform and semantically unambiguous way. Requirements for a unified energy data information model are presented in this paper.
Mit der Anwendung der Norm ISO 50001 und der einhergehenden Einführung eines Energiemanagementsystems (kurz EnMS) kann eine sukzessive Erhöhung der Energieeffizienz erreicht werden. Zur Umsetzung von Energie-Monitoring- oder Standby-Management-Funktionalitäten müssen Energiedaten in der Feldebene bereitgestellt werden und auf Edge-Devices oder SPSen mittels eines Energiemanagement-Programms ggf. im Datenformat angepasst, skaliert und auf eine etablierte Kommunikationsschnittstelle (z.B. basierend auf OPC UA- oder MQTT) abgebildet werden. Die Erstellung dieser Energiemanagement-Programme geht mit einem hohen Engineering-Aufwand einher, denn die Feldgeräte aus der heterogenen Feldebene stellen die Energiedaten nicht in einer standardisierten Semantik bereit. Um diesem Engineering-Aufwand entgegenzuwirken, wird ein Konzept für ein universelles Energiedateninformationsmodell (kurz UEDIM) vorgestellt. Dieses Konzept sieht die Bereitstellung der Energiedaten an das EnMS in einer semantisch standardisierten Form vor. Zur weiteren Entwicklung des UEDIM wird im Beitrag näher untersucht, in welcher Form Energiedaten in der Feldebene bereitgestellt werden können und welche Anforderungen für das UEDIM aufzustellen sind.